Ventilation Air Conditioning

Download Guide To Natural Ventilation in High Rise Office Buildings by Antony Wood PDF

By Antony Wood

Tall structures usually are not the one resolution for attaining sustainability via elevated density in towns yet, given the dimensions of present inhabitants shifts, the vertical urban is more and more being visible because the such a lot potential resolution for plenty of city facilities. in spite of the fact that, the total implications of concentrating extra humans on smaller plots of land by means of development vertically - even if for paintings, residential or relaxation capabilities - has to be greater researched and understood.

It is usually authorized that we have to lessen the strength equation – in either working and embodied phrases – of each part and method within the construction as a vital point in making it extra sustainable. Mechanical HVAC structures (Heating, air flow and Air-Conditioning) in tall place of work structures often account for 30-40 percentage of total construction strength intake. The elevated potency (or most likely even removal) of those mechanical structures – during the provision of average air flow – might hence be argued to be crucial unmarried step lets make in making tall structures extra sustainable.

This consultant units out suggestions for each section of the making plans, building and operation of normal air flow platforms in those constructions, together with neighborhood climatic components that have to be taken under consideration, the best way to plan for seasonal differences in climate, and the dangers in adopting diversified implementation innovations. the entire options are according to research of the examine findings from richly-illustrated overseas case studies.

Tried and confirmed ideas to real-life difficulties make this an important consultant for someone engaged on the layout and operation of tall constructions anyplace on the planet. this is often the 1st technical consultant from the Council on Tall constructions and concrete Habitat’s Tall structures & Sustainability operating workforce taking a look intensive at a key aspect within the production of tall constructions with a much-reduced environmental impression, whereas taking the in the direction of an appreciation of what constitutes a sustainable tall construction, and what components impact the sustainability threshold for tall.

Show description

Read or Download Guide To Natural Ventilation in High Rise Office Buildings PDF

Best ventilation & air conditioning books

Steam Generators and Waste Heat Boilers: For Process and Plant Engineers

Contains Worked-Out Real-World ProblemsSteam turbines and Waste warmth Boilers: For technique and Plant Engineers makes a speciality of the thermal layout and function facets of steam turbines, HRSGs and fireplace tube, water tube waste warmth boilers together with air warmers, and condensing economizers. Over one hundred twenty real-life difficulties are absolutely labored out that allows you to aid plant engineers in comparing new boilers or making adjustments to present boiler parts with out the help of boiler providers.

The Mass Retrofitting of an Energy Efficient—Low Carbon Zone

Maximizing reader insights into the strategic price of mass retrofits within the residential estate region via a close case learn research of the ‘Hackbridge project’, this publication makes use of this improvement to expand realizing of the way planners may well practice city regeneration according to a centralized plan.

2013 ASHRAE Handbook -- Fundamentals (IP) (Ashrae Handbook Fundamentals Inch-Pound System)

Buyers of the print model will obtain the CD-ROM in twin devices for no extra cost. clients can also buy the CD-ROM individually for $179. The 2013 ASHRAE guide: basics covers easy rules and knowledge utilized in the HVAC&R undefined. up-to-date with examine backed through ASHRAE and others, this quantity comprises 1,000 pages and 39 chapters protecting normal engineering info, uncomplicated fabrics, weather info, load and effort calculations, duct and pipe layout, and sustainability, plus reference tables for abbreviations and emblems, I-P to SI conversions, and actual homes of fabrics.

Optimum Cooling of Data Centers: Application of Risk Assessment and Mitigation Techniques

This booklet describes using unfastened air cooling to enhance the potency of, and cooling of, gear to be used in telecom infrastructures. mentioned at size is the cooling of verbal exchange install rooms similar to facts facilities or base stations, and this can be meant as a precious software for the folks designing and production key elements of communique networks.

Extra info for Guide To Natural Ventilation in High Rise Office Buildings

Sample text

2: Overall view from the west. R. Hamzah and Yeang 1 The climatic data listed for Penang was derived from the World Meteorological Organization (WMO) and Malaysia Meteorological Department. Case Study: Menara UMNO | 51 Balcony/Sky Court Plan Wind “Wing Walls” (on the south, southwest, and northeast façades – highlighted in green) are used to capture a wide range of wind directions. Windows adjacent to the Wing Walls and balconies allow for cross-ventilation at each floor. Additionally, windows along the west and southwest curving façade can be opened for direct ventilation.

Office layout flexibility may be restricted due to the façade cavity Books:  Briegleb, T. ) (2000) Ingenhoven Overdiek and Partners: High-Rise RWE AG Essen. Birkhäuser: Basel.  Feireiss, K. (2002) Ingenhoven Overdiek and Partners, Energies. Birkhäuser: Basel, pp. 214–241. Analysis – Considerations The following areas could be causes for concern if adopting similar strategies in other buildings and should therefore be considered: References & Further Reading Owner/Developer: Hochtief AG Design Architect: ingenhoven architects Structural Engineer: Buro Happold; Hochtief AG MEP Engineer: HL-Technik AG Beratende Ingenieure; IGK Ingenieurgemeinschaft Kruck; Buro Happold Environmental Engineer: Geocontrol Umwelttechnische Beratung Main Contractor: Hochtief AG Other Consultants: Josef Gartner and Company (Façade Consultant)  Ingenhoven, C.

The mixed-mode system thus combines passive wind-induced natural ventilation with a minimal active mechanical air-conditioning system. The Wind Core/escalator void also serves as the return path duct when mechanical systems/conditioned air are used. The air outlets on the eighteenth-level Wind Floor also serve as air exhausts in both natural and mechanical ventilation modes. , winter) when the temperature of the external cold air flowing directly through the occupied spaces would be too low. At that time, the building is heated by the HVAC system at a constant supply temperature.

Download PDF sample

Rated 4.11 of 5 – based on 36 votes